Technical Data

 

 

Designation   Easypell 16 Easypell 20 Easypell 25 Easypell 32
Boiler - rated power kW 16 20 25 32
Boiler partial load kW 5 6 8 10
Width - total (B) mm 1147 1147 1179 1179
Width - boiler (C) mm 695 695 728,5 728,5
Height - boiler (H) mm 1091 1091 1242 1242
Height - filler unit (F) mm 1417 1417 1517 1517
Height - filling unit open mm 1930 1930 2030 2030
Depth - boiler (T) mm 752 752 796,5 796,5
Min. door width for access mm 720 720 165 765
Flow / return connection inches 1'' 1'' 5/4'' 5/4''
Flow / return connection height mm 905 905 1110 1110
Flue pipe connecting height mm 645 645 844 844
Weight kg 320 320 400 400
Boiler efficiency rated power % 93,1 93,6 94,3 95,3
Boiler efficiency partial load % 91,5 92,3 93,3 94,7
Energy efficiency class   A+ A+ A+ A+
EEI Energy Efficiency Index   118,67 119,84 121,18 123,04
Water content l 70 70 108 108
Hopper capacity kg 165 165 190 190
Flame chamber temperature °C 700-900 700-900 700-900 700-900
Draft requirement rated power/partial load mbar 0,08/0,03 0,08/0,03 0,08/0,03 0,08/0,03
Flue gas temperature rated power °C 160 160 160 160
Flue gas temperature partial load °C 100 100 100 100
Flue gas tube diameter (at the boiler) mm 130 130 150 150
Flue diameter   as per chimney calculation as per chimney calculation as per chimney calculation as per chimney calculation
Flue constitution   withstand humidity withstand humidity withstand humidity withstand humidity
Electrical connection   230 VAC, 50 Hz, 10 A 230 VAC, 50 Hz, 10 A 230 VAC, 50 Hz, 10 A 230 VAC, 50 Hz, 10 A
Noise level dB 43,7 ± 3,2 43,7 ± 3,2 43,7 ± 3,2 43,7 ± 3,2
Go to top