Technical data & download wood boiler
Here you can find the technical overview of our EASYPELL wood pellet boiler.
| EASYPELL Wood-Log Boiler | EPW 22 | EPW 32 |
|---|---|---|
| Nominal heat output (kW) | 22 | 32 |
| Heat output range (kW) | 11 - 22 | 16 - 32 |
| Boiler class EN 303-5:2021 | 5 | |
| Required negative chimney pressure (Pa) | 10 | |
| Water volume in the boiler | 130 | 140 |
| Flue gas temperature at nominal heat output | 155 | 160 |
| Flue gas temperature at minimum heat output | 105 | |
| Minimum operating time at nominal output (nominal value Q ) (h) | 3 | |
| Min. water inlet temp. at the return water connection (°C) | 60 | |
| Max. Temperature (°C) | 90 | |
| Fuel type | A, logs, according to standard 14964-5 | |
| Moisture content of the fuel (%) | maximum 25 % | |
| Length of fuel (mm) | maximum 550 | |
| Capacity of the fuel loading chamber (L) | 120 | |
| Type of combustion chamber | UNDER PRESSURE | |
| Required minimum storage volume (tank) next to the boiler | according to EN 303-5:2021 | |
| Supply voltage (V~) | 230 | |
| Frequency (Hz) | 50 | |
| Weight (kg) | 534 | 546 |
| Max. Operating pressure (bar) | 3 | |
| Flue gas pipe - outer diameter (mm) | 150 | |
| Heater in operation | with ventilator, under non-condensing conditions | |
| Energy efficiency class of the boiler | A+ | |